Norsok M-650 Qualification Forging Flanges
NORSOK M-650 qualified forging flanges are high-integrity forged flanges manufactured and tested in accordance with NORSOK M-650 requirements for critical offshore and oil & gas applications.
This qualification ensures that the manufacturer, material, and manufacturing process are capable of producing consistent, defect-free forgings suitable for harsh service conditions.
What Is NORSOK M-650?
NORSOK M-650 is a Norwegian standard that defines qualification requirements for manufacturers of special materials, including forgings, castings, pipes, and fittings, used in offshore and petroleum industries.
Scope of NORSOK M-650 Qualified Forging Flanges
NORSOK M-650 qualification typically applies to forged flanges manufactured to standards such as:
-
ASME B16.5 / ASME B16.47
-
EN 1092-1
-
Custom project specifications
Qualified materials may include:
ASTM A182 F51,
ASTM A182 F53,
ASTM A182 F55,
ASTM A182 F60,
ASTM B564 N08825,
ASTM B564 N06625
ASTM A182 F51 Forging Flanges Of Norsok M-650 Qualification |
||||||||||
| No. | Test | Product Requirement | ||||||||
| 1 | Chemical Composition | C | Mn | P | S | Si | Cr | Ni | Mo | N |
| ≤0.03 | ≤2 | ≤0.03 | ≤0.02 | ≤1 | 21-23 | 4.5-6.6 | 2.5-3.5 | 0.14-0.20 | ||
| 2 | Tensile Test | Tensile Strenght ≥620Mpa ,Yield Strenght (0.2% offset)≥450Mpa,Elongation After Fracture % (G=50mm)≥25 | ||||||||
| 3 | Impact Test | ASTM A370 (Test temp – 46℃ Avg ≥45J Single ≥35) | ||||||||
| 4 | Metallographic Analysis | ASTM E 562-19 | ||||||||
| Ferrite Content 35%~55% | ||||||||||
| ASTM A923-14 Method A | ||||||||||
| 5 | Pitting Conrrosion Test | ASTM G48 Method A | ||||||||
ASTM A182 F60 Forging Flanges Of Norsok M-650 Qualification |
||||||||||
| No. | Test | Product Requirement | ||||||||
| 1 | Chemical Composition | C | Mn | P | S | Si | Cr | Ni | Mo | N |
| ≤0.03 | ≤2 | ≤0.03 | ≤0.02 | ≤1 | 22-23 | 4.5~6.5 | 3.0-3.5 | 0.14-0.20 | ||
| 2 | Tensile Test | Tensile Strenght ≥655Mpa ,Yield Strenght (0.2% offset)≥450Mpa,Elongation After Fracture % (G=50mm)≥25 | ||||||||
| 3 | Impact Test | ASTM A370 (Test temp – 46℃ Avg ≥45J Single ≥35) | ||||||||
| 4 | Metallographic Analysis | ASTM E 562-19 | ||||||||
| Ferrite Content 35%~55% | ||||||||||
| ASTM A923-14 Method A | ||||||||||
| 5 | Pitting Conrrosion Test | ASTM G48 Method A | ||||||||
ASTM A182 F53 Forging Flanges Of Norsok M-650 Qualification |
|||||||||||
| No. | Test | Product Requirement | |||||||||
| 1 | Chemical Composition | C | Mn | P | S | Si | Cr | Ni | Mo | N | Cu |
| ≤0.03 | ≤1.2 | ≤0.035 | ≤0.02 | ≤0.8 | 24-26 | 6~8 | 3~5 | 0.24-0.32 | ≤0.5 | ||
| 2 | Tensile Test | Tensile Strenght ≥750Mpa ,Yield Strenght (0.2% offset)≥550Mpa,Elongation After Fracture % (G=50mm)≥25,HBW≤310 | |||||||||
| 3 | Impact Test | ASTM A370 (Test temp – 46℃ Avg ≥45J Single ≥35) | |||||||||
| 4 | Metallographic Analysis | ASTM E 562-19 | |||||||||
| Ferrite Content 35%~55% | |||||||||||
| ASTM A923-14 Method A | |||||||||||
| 5 | Pitting Conrrosion Test | ASTM G48 Method A | |||||||||
ASTM A182 F55 Forging Flanges Of Norsok M-650 Qualification |
||||||||||||
| No. | Test | Product Requirement | ||||||||||
| 1 | Chemical Composition | C | Mn | P | S | Si | Cr | Ni | Mo | N | W | Cu |
| ≤0.03 | ≤1 | ≤0.03 | ≤0.01 | ≤1 | 24-26 | 6~8 | 3~4 | 0.2-0.3 | 0.5-1.0 | 0.5-1.0 | ||
| 2 | Tensile Test | Tensile Strenght 750-895 Mpa ,Yield Strenght (0.2% offset)≥550Mpa,Elongation After Fracture % (G=50mm)≥25 | ||||||||||
| 3 | Impact Test | ASTM A370 (Test temp – 46℃ Avg ≥45J Single ≥35) | ||||||||||
| 4 | Metallographic Analysis | ASTM E 562-19 | ||||||||||
| Ferrite Content 35%~55% | ||||||||||||
| ASTM A923-14 Method A | ||||||||||||
| 5 | Pitting Conrrosion Test | ASTM G48 Method A | ||||||||||
ASTM B564 N08825 Forging Flanges Of Norsok M-650 Qualification |
||||||||||||
| No. | Test | Product Requirement | ||||||||||
| 1 | Chemical Composition | Ni | Cr | Fe | Mn | C | Cu | Si | S | Mo | Al | Ti |
| 38~46 | 19.5~23.5 | ≤22 | ≤1 | ≤0.05 | 1.5~3 | ≤0.5 | ≤0.03 | 2.5~3.5 | ≤0.2 | 0.6~1.2 | ||
| 2 | Tensile Test | Tensile Strenght ≥585Mpa ,Yield Strenght (0.2% offset)≥241Mpa,Elongation After Fracture % (G=50mm)≥30 | ||||||||||
NORSOK M-650 qualified forging flanges provide the highest level of reliability for critical offshore and oil & gas applications.
Download FAQ-NORSOK-M650-Rev4
NORSOK M-650 Products
ASTM A182 F51 Weld Neck Flanges
ASTM A182 F53 Weld Neck Flanges
ASTM A182 F55 Weld Neck Flanges